TECHNICAL DATA
APPLICATIONS CAPACITY
Max.number of collectors:1
Max.number of storage tanks:1
Max.number of relays:4
Max.number of sensors:5
Max.number of visualization application system: 1
FRT:1* Rotary vane type electron flow meter
Size of Keypad:120mm x 120mm x 18mm
Size of Controller(1.5KW version): 187mm x128mm x46mm
Size of Controller(3KW version): 218mm x165mm x55mm
Size of Controller(4KW version): 218mm x165mm x55mm
Power supply: AC100-240V50-60Hz
Power consumption: < 2.5W
Rated impulse voltage: 2.5KV
Housing: Plastic ABS
Protection type: IP41
Mounting: Wall mounting
Operation: 10 push buttons at the front cover.
Accuracy of temperature measuring: ± 0.1℃
Range of collector temperature measuring: -10℃ ~220℃
Range of tank temperature measuring: 0℃C ~110℃
Suitable power of pump: 3 pump possible to be connected
Suitable power of HK (backup heating):
1pc(1.5KW version) ˂1.5KW
1pc(3KW version) ˂3KW
1pc(4KW version) ˂4KW
Inputs: 5 sensors
1pcs*Pt1000 sensor (≤500℃) for collector (silicon cable≤280℃)
4pcs*NTC10K B3950 sensor (≤ 135℃) for tank (PVC cable ≤105℃)
1*FRT Rotary vane type electron flow meter
Outputs: 4 relays for circulation pump and backup heating
3*Electromagnetic relay Max.current 2A
HK relay(1.5KW version):10A
HK relay(3KW version):15A
HK relay(4KW version):20A
Ambient temperature: -10℃ ~ 50℃.
Water proof grade: IP41
MAIN FUNCTIONS
DATE---Date setting
Timed heat---backup heating
Circle---Hot water circulation
LOAD---Setup Loading tank1
COL---Collector1
PUMP---Pump control mode
COOL---Cooling function
AUX---Auxiliary function
MAN---Manual mode
BLPR---Blocking protection function
OTDI---Thermal disinfection function
FS---Flow meter type selection.
UNIT---C-F unit switch
RST---factory setting
PASS--- password set
Holiday function
Screen Protection
Trouble Protection
Trouble Checking